Weight |
kg |
272 |
Height |
mm |
1430 |
Width |
mm |
665 |
Depth |
mm |
830 |
Flue pipe diameter |
mm |
100 |
Draft |
mbar |
0,10 |
Pellet tank capacity |
kg |
75 |
Electricity consumption at start |
W |
503 |
Electricity consumption during operation |
W |
114 |
Standby power consumption |
W |
4 |
Nominal voltage |
Vac |
220-240 |
Nominal frequency |
Hz |
50 |
Water pipe diameter |
” |
1 |
Safety valve pipe diameter |
” |
1/2 |
Pump flow rate |
l/h |
1300 |
Expansion dish |
l |
8 |
Exhaust gas temperature in nominal mode |
°C |
119 |
Exhaust gas temperature in minimum operating mode |
°C |
68,5 |
Amount of water in the boiler |
l |
72 |
Boiler power |
kW |
min 6 – max 23,7 |
Pellet consumption |
kg/h |
min 1,41 – max 5,47 |
Energy utilization |
% |
min 89,6 – nominal 91,6 |
Water temperature setting range |
°C |
min 60 – max 80 |
Minimum return water temperature |
°C |
50 |
Boiler water pressure |
bar |
min 0,60 – max 2,50 |
Recommended pellet class |
EN303-5 EN plus |
C1 – A1 |
Boiler class |
– |
5 |
Boiler energy efficiency |
– |
A+ |
Heating surface |
m² |
130-220 |